Room Lighting Calculator

Total lumens and number of luminaires needed to reach a target illuminance.

Results

Luminous flux 12,500 lm
Lamps needed 9
Luminous flux 6000 lm

What this tool does

Not all the light a lamp emits reaches the working plane: some is absorbed by walls and ceiling, and output falls as fixtures age and collect dust. The utilisation and maintenance factors account for both. Common targets are 150 lux for a corridor, 300 for a living room and 500 for office or workshop tasks.

Formula

lumens = lux × area ÷ (utilisation factor × maintenance factor)

Variables

SymbolMeaningUnit
aArea
lxTarget illuminancelx
ufEfficiency%
mfPercentage%
llLumens per lamplm
LMLuminous fluxlm
NLamps needed
LALuminous fluxlm

Worked example

  • Area20 m²
  • Target illuminance300 lx
  • Efficiency60 %
  • Percentage80 %
  • Lumens per lamp1500 lm
  • Luminous flux12,500 lm
  • Lamps needed9
  • Luminous flux6000 lm

Limitations

  • The result is an estimate based only on the values you type. Real situations often include factors this calculator does not know about.
  • For work that must comply with a standard or be signed off, check the result against the applicable code and have it reviewed by a qualified engineer.