Underfloor Heating Pipe Calculator

Metres of pipe and number of loops for an underfloor heating circuit.

Results

Pipe length 176.7 m
Number of loops 2
Length 88.3 m
Pipe length 166.7 m

What this tool does

Pipe length is simply area divided by spacing, plus the run out to the manifold and back. Loops are limited to around 100 metres for 16 mm pipe because a longer circuit needs too much pump pressure and arrives at the far end already cold — so the area gets split into several balanced loops.

Formula

length = area ÷ spacing

Variables

SymbolMeaningUnit
aArea
spPipe spacingcm
ldDistancem
mlMaximum loop lengthm
LPipe lengthm
NNumber of loops
LLLengthm
LAPipe lengthm

Worked example

  • Area25 m²
  • Pipe spacing15 cm
  • Distance5 m
  • Maximum loop length100 m
  • Pipe length176.7 m
  • Number of loops2
  • Length88.3 m
  • Pipe length166.7 m

Limitations

  • The result is an estimate based only on the values you type. Real situations often include factors this calculator does not know about.
  • For work that must comply with a standard or be signed off, check the result against the applicable code and have it reviewed by a qualified engineer.