Hydraulic Accumulator Sizing Calculator (Bladder, Piston and Diaphragm)

The size of accumulator needed to deliver a given volume of oil between a low and a high working pressure, from the gas precharge, with the gas volumes at both ends.

Results

Accumulator size needed 13.87 L
Gas volume at the lowest pressure 12.88 L
Gas volume at the highest pressure 7.88 L
Share of the accumulator that is usable oil 36.0 %

What this tool does

An accumulator stores oil by compressing a nitrogen cushion, and the gas law (P₁V₁ᵏ = P₂V₂ᵏ) says how much oil comes out as the pressure falls. Use absolute pressures — the calculator adds atmospheric pressure to the gauge values you enter. A fast discharge in a second or two is nearly adiabatic (k = 1.4); a slow one leaves time for heat to flow in, which is isothermal (k = 1) and gives more oil for the same size. Precharge is usually set at roughly 80–90 % of the lowest working pressure, and a ratio of highest working pressure to precharge beyond about 4:1 is hard on a bladder.

Formula

V₀ = ΔV ÷ [ (P₀/P₁)^(1/k) − (P₀/P₂)^(1/k) ] (absolute pressures; k = 1.4 fast, 1 slow)

Variables

SymbolMeaningUnit
dvVolume of oil you need to drawL
a0Gas precharge pressure (gauge)bar
a1Lowest working pressure (gauge)bar
a2Highest working pressure (gauge)bar
kkGas behaviour—
V0Accumulator size neededL
V1Gas volume at the lowest pressureL
V2Gas volume at the highest pressureL
UFShare of the accumulator that is usable oil%

Worked example

  • Volume of oil you need to draw5 L
  • Gas precharge pressure (gauge)90 bar
  • Lowest working pressure (gauge)100 bar
  • Highest working pressure (gauge)200 bar
  • Gas behaviour1.4
  • Accumulator size needed13.87 L
  • Gas volume at the lowest pressure12.88 L
  • Gas volume at the highest pressure7.88 L
  • Share of the accumulator that is usable oil36.0 %

Limitations

  • For work that must comply with a standard or be signed off, check the result against the applicable code and have it reviewed by a qualified engineer.
  • The formula assumes ideal conditions: no friction losses, no air resistance and no efficiency losses unless you enter them.