PCB Trace Width Calculator (IPC-2221, Current and Temperature Rise)

Width of a copper trace for a current and an accepted temperature rise, on an outer or inner layer, with its resistance, voltage drop and power loss.

Results

Trace width needed 1.37 mm
Trace width needed (mil) 53.8 mil
Copper cross-section 0.048 mm²
Resistance of that length at 20 °C 17.97 mΩ
Voltage drop along it 53.9 mV
Power lost in it 161.8 mW
How it changes
Trace width neededCurrent the trace must carry 0.1 – 9.0. Trace width needed: 0.0125417 → 6.22103Trace width needed024682.04.06.08.0Current the trace must carry (A)

The dashed line marks the value you entered.

What this tool does

IPC-2221 gives the cross-section a trace needs as A = [I ÷ (k ΔT^0.44)]^(1/0.725) in square mils, with k = 0.048 for outer layers, where air cools the copper, and 0.024 for inner ones. The width follows from the copper weight: 1 oz/ft² is about 35 µm (1.378 mil) thick, so 3 A with a 10 °C rise needs roughly 1.4 mm on an outer layer of 1 oz copper. The curves behind it come from old measurements, valid up to about 35 A, and IPC-2152 later showed that nearby planes and board thickness change the answer; treat the result as a good starting point, and add margin for hot enclosures.

Formula

A = [I ÷ (k ΔT^0.44)]^(1 ÷ 0.725) in mil² · width = A ÷ (1.378 mil × oz) · k = 0.048 outer, 0.024 inner (IPC-2221)

Variables

SymbolMeaningUnit
iCurrent the trace must carryA
dtTemperature rise you accept°C
ozCopper weightoz
lyWhere the trace is—
lgLength of the tracemm
WMTrace width neededmm
WITrace width needed (mil)mil
ARCopper cross-sectionmm²
RSResistance of that length at 20 °CmΩ
VDVoltage drop along itmV
PLPower lost in itmW

Worked example

  • Current the trace must carry3 A
  • Temperature rise you accept10 °C
  • Copper weight1 oz
  • Where the trace is1
  • Length of the trace50 mm
  • Trace width needed1.37 mm
  • Trace width needed (mil)53.8 mil
  • Copper cross-section0.048 mm²
  • Resistance of that length at 20 °C17.97 mΩ
  • Voltage drop along it53.9 mV
  • Power lost in it161.8 mW

Limitations

  • For work that must comply with a standard or be signed off, check the result against the applicable code and have it reviewed by a qualified engineer.
  • The result is an estimate based only on the values you type. Real situations often include factors this calculator does not know about.