Poiseuille Flow Calculator (Hagen–Poiseuille Law for Tubes and Blood Vessels)

Flow rate of a thick liquid through a narrow tube from the pressure difference, tube size, length and viscosity, with a check that the flow is smooth enough for the law to hold.

Results

Flow rate 14.726 mL/min
Mean speed of the fluid 0.3125 m/s
Reynolds number 313
How the fluid is moving Laminar — smooth, in layers
Shear stress at the wall 2.50 Pa
How it changes
Flow rateDiameter 0.25 – 2.00. Flow rate: 0.0575243 → 235.619Flow rate0501001502002500.501.001.502.00Diameter (mm)

The dashed line marks the value you entered.

What this tool does

The Hagen–Poiseuille law says flow through a tube grows with the fourth power of its radius: halve the radius and you get one sixteenth of the flow, which is why a slightly narrowed artery or a blocked needle matters so much. It holds only for smooth, layered (laminar) flow, so the tool also gives the Reynolds number; above about 2300 the flow turns turbulent and the law overestimates it. Viscosity falls as liquids warm — water is about 1.0 mPa·s at 20 °C and 0.65 at 40 °C.

Formula

Q = π r⁴ ΔP ÷ (8 μ L) (Hagen–Poiseuille) · τ_wall = ΔP r ÷ 2L · Re = ρ v D ÷ μ

Variables

SymbolMeaningUnit
dmDiametermm
lgLengthm
dkPressure difference between the two endskPa
muDynamic viscositymPa·s
roDensitykg/m³
QFlow ratemL/min
VMean speed of the fluidm/s
REReynolds number—
RGHow the fluid is moving—
TWShear stress at the wallPa

Worked example

  • Diameter1 mm
  • Length0.5 m
  • Pressure difference between the two ends5 kPa
  • Dynamic viscosity1 mPa·s
  • Density1000 kg/m³
  • Flow rate14.726 mL/min
  • Mean speed of the fluid0.3125 m/s
  • Reynolds number313
  • How the fluid is movingLaminar — smooth, in layers
  • Shear stress at the wall2.50 Pa

Limitations

  • The formula assumes ideal conditions: no friction losses, no air resistance and no efficiency losses unless you enter them.
  • For work that must comply with a standard or be signed off, check the result against the applicable code and have it reviewed by a qualified engineer.