Shaft power a pump needs for a given flow, head and efficiency.

Results

Power 2.919 kW
Power 2.043 kW

What this tool does

Hydraulic power is what reaches the liquid; shaft power is that divided by the pump efficiency. Real pumps sit between 55 and 85 percent depending on size and duty point.

Formula

P = ρ × g × Q × H ÷ η

Variables

SymbolMeaningUnit
qFlow ratem³/h
hHeightm
dDensitykg/m³
efEfficiency%
PPowerkW
PHPowerkW

Worked example

  • Flow rate30 m³/h
  • Height25 m
  • Density1000 kg/m³
  • Efficiency70 %
  • Power2.919 kW
  • Power2.043 kW

Limitations

  • The formula assumes ideal conditions: no friction losses, no air resistance and no efficiency losses unless you enter them.
  • The result is an estimate based only on the values you type. Real situations often include factors this calculator does not know about.