RC Filter Frequency Response Calculator

Gain in dB, output-to-input ratio and phase shift of a first-order RC low-pass or high-pass filter at any frequency, with its response curve drawn.

Results

Gain at that frequency -16.07 dB
Cut-off frequency 159.15 Hz
Output ÷ input voltage 0.1572
Phase shift -80.96 °
How it changes
Gain at that frequencySignal frequency 16 – 1592. Gain at that frequency: -0.0432137 → -20.0432Gain at that frequency-25-20-15-10-5050010001500Signal frequency (Hz)

The dashed line marks the value you entered.

What this tool does

At the cut-off frequency 1 ÷ 2πRC the output is down 3 dB — about 71 % of the input voltage — and the phase has shifted 45°. Beyond it a single RC stage falls off by only 20 dB per decade, a gentle slope, which is why real filters often cascade several stages or use active designs. The figures assume the source has negligible resistance and the next stage draws no current; a load that does changes the cut-off.

Formula

f_c = 1 ÷ (2πRC) · low-pass |H| = 1 ÷ √(1 + (f/f_c)²) · high-pass |H| = (f/f_c) ÷ √(1 + (f/f_c)²)

Variables

SymbolMeaningUnit
rkResistancekΩ
cnCapacitancenF
fSignal frequencyHz
tyFilter type—
GGain at that frequencydB
FCCut-off frequencyHz
HOutput ÷ input voltage—
PHPhase shift°

Worked example

  • Resistance10 kΩ
  • Capacitance100 nF
  • Signal frequency1000 Hz
  • Filter type1
  • Gain at that frequency-16.07 dB
  • Cut-off frequency159.15 Hz
  • Output ÷ input voltage0.1572
  • Phase shift-80.96 °